AC/DC HIGH VOLTAGE DIVIDER VT1005

Inverters used in rail and power system applications convert high-voltage power. To measure the efficiency of such conversions, it’s necessary to measure voltages of 1000 V and above. The VT1005 divides voltages of up to 5000 V and outputs them to a power analyzer.In order to measure the efficiency of high-efficiency inverters with a high degree of precision, you need to be able to accurately measure power from DC to high frequencies. Thanks to its excellent frequency flatness, the VT1005 makes possible accurate measurement at frequencies ranging from the fundamental wave to switching-frequency components.

Description

Basic specifications
Accuracy guaranteed for 1 year
Maximum rated voltage 5000 V rms, ±7100 V peak (*1)
Maximum rated voltage
(line-to-ground)
No measurement category: 5000 V AC/DC (*2)
Measurement category II: 2000 V AC/DC (*3)
Measurement category III: 1500 V AC/DC (*4)
Voltage dividing ratio 1000:1
Measurement accuracy ±0.08%(DC), ±0.04%(50/60 Hz), ±0.17% (50 kHz)
Frequency
flatness
Band where amplitude falls within ±0.1% range: 200 kHz (typical)
Band where phase falls within ±0.1° range: 500 kHz (typical) (*5)
Measurement bandwidth DC to 4 MHz (Amplitude and phase accuracy specified up to 1 MHz)
Common-mode voltage
rejection ratio (CMRR)
50 Hz/60 Hz: 90 dB(Typical)
100 kHz: 80 dB (Typical)
Measurement method Differential input
Operating temperature and humidity range -10°C to 50°C (14°F to 122°F), 80% RH or less (non-condensing)
Storage temperature and humidity range −20°C to 60°C (-4°F to 140°F), 80% RH or less (non-condensing)
Standards Safety: EN 61010
EMC: EN 61326 Class A
Power supply 100 V to 240 V AC (50/60 Hz)
Dimensions and Weight Approx. 195.0 mm (7.68 in) W × 83.2 mm (3.28 in) H × 346.0 mm (13.62 in) D mm
Approx. 2.2 kg (77.6 oz.)
Included accessories – L1050-01 Voltage Cord ×1 (1.6 m/ 5.25 ft)
– L9217 Connection Cord ×1 (insulated BNC, 1.6 m/ 5.25 ft)
– 9704 Conversion Adapter ×1 (insulated-female BNC-to-banana plug)
– Power cord ×1
  • *1:Within the frequency derating range
    No measurement category: Applicable to the measurement of circuits that are not directly connected to the main power supply.
    EXAMPLE: Measurement on the secondary-side equipment from the socket outlet of fixed installation through a transformer, etc.
  • *2:±7100 V peak, Anticipated transient overvoltage 0 V
  • *3:Anticipated transient overvoltage 12000 V
  • *4:Anticipated transient overvoltage 10000 V
  • *5:After phase correction by the power analyzer
Measurement accuracy
Frequency
Amplitude
±(% of reading + % of full scale)
Phase
DC
0.03% + 0.05%
DC < f < 30 Hz
0.2% + 0.1%
±0.1°
30 Hz ≤ f < 45 Hz
0.1% + 0.1%
±0.1°
45 Hz ≤ f ≤ 66 Hz
0.02% + 0.02%
±0.06°
66 Hz < f ≤ 100 Hz
0.1% + 0.02%
±0.12°
100 Hz < f ≤ 1 kHz
0.1% + 0.02%
±0.2°
1 kHz < f ≤ 5 kHz
0.15% + 0.02%
±0.4°
5 kHz < f ≤ 50 kHz
0.15% + 0.02%
±(0.08 × f kHZ)°
50 kHz < f ≤ 100 kHz
0.5% + 0.02%
±(0.08 × f kHZ)°
100 kHz < f ≤ 300 kHz
1.5% + 0.5%
±(0.08 × f kHZ)°
300 kHz < f ≤ 1 MHz
5.0% + 0.5%
±(0.08 × f kHZ)°
Frequency band
4 MHz(-3 dB Typical)