The WGA-710C is a multi-functional Instrumentation Amplifier with a digital display. A low noise amplifier is adopted to ensure stable measurement.
WGA-710C-0E, Standard
Models:
- WGA-710C-0E: Power supply 100 VAC
- WGA-710C-0 A115E: Power supply 115 VAC
- WGA-710C-0 A200E: Power supply 200 VAC
- WGA-710C-0 A220E: Power supply 220 VAC
Channels: 1
Applicable Transducers: Strain-gage Transducers
Compatible Bridge Resistance: 87.5 Ω to 10 kΩ (Up to 4 transducers with 350 Ω bridge resistance connected in parallel)
Sampling Speed: Approx. 15 times/s
External Signal:
- D/Z
- T/H
- H/M
- Non-voltage contact signal
- Open collector (NPN)
WGA-710C-1E, With BCD Data Output
Models:
- WGA-710C-1E: Power supply 100 VAC
- WGA-710C-1 A115E: Power supply 115 VAC
- WGA-710C-1 A200E: Power supply 200 VAC
- WGA-710C-1 A220E: Power supply 220 VAC
It enables WGA-710C-1E to output indicated values as BCD (binary coded decimal).
With BCD Data Output
Output Mode: Isolated open collector (NPN)
Driving Capacity: 30 VDC, 20 mA
Output Signals:
- 4-digital BCD value
- Minus sign
- OVER signal
- Print command (EOC); positive or negative logic selected by the switch.
Input Command:
- BCD hold
- Output disable
- Negative logic
WGA-710C-2E, With EIA-232-D (RS-232C)
Models:
- WGA-710C-2E: Power supply 100 VAC
- WGA-710C-2 A115E: Power supply 115 VAC
- WGA-710C-2 A200E: Power supply 200 VAC
- WGA-710C-2 A220E: Power supply 220 VAC
EIA-232-D (RS-232C) enables this model to transmit indicated data and status signals and write preset high/low limit values to external equipment without digitizing.
With EIA-232-D
Signal System: RS-232C full duplex system
Transmission Mode: Asynchronous
Baud Rate: 4800 bps
Bit Structure:
- 7 data bits,
- 1 stop bit
- Odd parity bit
WGA-710C-3E, With Analog Amplifier
Models:
- WGA-710C-3E: Power supply 100 VAC
- WGA-710C-3 A115E: Power supply 115 VAC
- WGA-710C-3 A200E: Power supply 200 VAC
- WGA-710C-3 A220E: Power supply 220 VAC
This model is designed to amplify and output the analog signal of transducer to external equipment without digitizing.
With Analog Amplifier
Measuring Range: ±3.2 mV/V
Zero Adjustment Range: ±2.5 mV/V
Sensitivity Adjustment Range: 0.5 to 3.0 mV/V is adjusted to 10 V
Calibration: 1 mV/V ±0.1%
Voltage Output: ±10 V (Load resistance 2 kΩ or more) Nonlinearity: Within ±0.03% FS
Current Output: 4 to 20 mA (Load resistance 350 Ω or less (Corresponding to voltage output of 0 to 10 V)
Nonlinearity: Within ±0.1%FS
Frequency Response: DC to 1 kHz
WGA-710C-4E, With DA Converter
Models:
- WGA-710C-4E: Power supply 100 VAC
- WGA-710C-4 A115E: Power supply 115 VAC
- WGA-710C-4 A200E: Power supply 200 VAC
- WGA-710C-4 A220E: Power supply 220 VAC
This model can output an analog signal with the digital indication. Digital zeroing, hold and smoothing functions are provided.
With DA Converter
Output Analog Signal Level: +10 V, 20 mA for the full scale setting on the case
Zero Adjustment Range: Within ±10%FS
Sensitivity Adjustment Range: Within ±10%FS
Nonlinearity: Within ±0.1%FS
Frequency Response: Depends on the sampling cycle (Approx. 15 times/s)
Withstand Voltage: 500 VAC for one minute with the case
Voltage Output: 0 to 10 V (Load resistance 2 kΩ or more)
Current Output: 4 to 20 mA (Load resistance 350 Ωor less (Corresponding to voltage output of 0 to 10 V)
WGA-710C-5E, With Isolation Analog Amplifier
Models:
- WGA-710C-5E: Power supply 100 VAC
- WGA-710C-5 A115E: Power supply 115 VAC
- WGA-710C-5 A200E: Power supply 200 VAC
- WGA-710C-5 A220E: Power supply 220 VAC
This model is designed to amplify and output the analog signal of a transducer to external equipment without digitizing.
WGA-710C-6E, With 8-step Comparator
Models:
- WGA-710C-6E: Power supply 100 VAC
- WGA-710C-6 A115E: Power supply 115 VAC
- WGA-710C-6 A200E: Power supply 200 VAC
- WGA-710C-6 A220E: Power supply 220 VAC
This model provides 4 sets of high/low limits for comparison. The high/low limit relay (transformer contact) outputs the result of 1 set of high/low limits compared.
With 8-step Comparator
Comparison Points: 8 (4 each high/low limits)
Setting Methods: Select from external contact input and set by the panel keys
Setting Range: 0 to ±9999
Output Modes: Isolated open collector (NPN)
Drive Capacity: 30 VDC, 20 mA
WGA-710C-12E, With BCD Data Output and EIA-232-D (RS-232C)
Models:
- WGA-710C-12E: Power supply 100 VAC
- WGA-710C-12 A115E: Power supply 115 VAC
- WGA-710C-12 A200E: Power supply 200 VAC
- WGA-710C-12 A220E: Power supply 220 VAC
This model enables simultaneous use of BCD data output and RS-232C.
With BCD Data Output
Output Mode: Isolated open collector (NPN)
Driving Capacity: 30 VDC, 20 mA
Output Signals:
- 4-digital BCD value
- Minus sign
- OVER signal
- Print command (EOC); positive or negative logic selected by the switch.
Input Command:
- BCD hold
- Output disable
- Negative logic
Input Mode: Non-voltage contact signal or open collector (NPN)
With EIA-232-D
Signal System: RS-232C full duplex system
Transmission Mode: Asynchronous
Baud Rate: 4800 bps
Bit Structure:
- 7 data bits, 1 stop bit
- Odd parity bit
WGA-710C-14E, With BCD Data Output and DA Converter
Models:
- WGA-710C-14E: Power supply 100 VAC
- WGA-710C-14 A115E: Power supply 115 VAC
- WGA-710C-14 A200E: Power supply 200 VAC
- WGA-710C-14 A220E: Power supply 220 VAC
This model enables simultaneous use of BCD data output and DA converter.
With DA Converter
Output Analog Signal Level: +10 V, 20 mA for the full scale setting on the case
Zero Adjustment Range: Within ±10%FS
Sensitivity Adjustment Range: Within ±10%FS
Nonlinearity: Within ±0.1%FS
Frequency Response: Depends on the sampling cycle (Approx. 15 times/s)
Withstand Voltage: 500 VAC for one minute with the case
Voltage Output: 0 to 10 V (Load resistance 2 kΩ or more)
Current Output: 4 to 20 mA (Load resistance 350 Ω or less)(Corresponding to voltage output of 0 to 10 V)
With BCD Data Output
Output Mode: Isolated open collector (NPN)
Diving Capacity: 30 VDC, 20 mA
Output Signals:
- 4-digital BCD value
- Minus sign
- OVER signal
- Print command (EOC); positive or negative logic selected by the switch.
Input Command:
- BCD hold
- Output disable
- Negative logic
Input Mode: Non-voltage contact signal or open collector (NPN)